Monday, February 16, 2009

Libraries open up a world of surprises

Library ceiling

Do you see what I see?

Yes! That's fiberglass insulation! But what is fiberglass insulation doing under this untouched plaster? Right - not so untouched.

Library ceiling

I must credit the quality of the plaster work on whoever did the work here - it is really impressive. The ceiling is made of a material that appears to be similar to drywall, only a bit more dense and only about 16" wide. It is about 5/8" thick and runs perpendicular to the joists. The seams on the joists are held together by metal lathe and a layer of plaster about 1/2" thick. If not for the water, this repair work would have been bulletproof. The metal lathe gripped the crown moulding at the edges - there's no way I could have gotten it apart.

Guardian Fiberglass

Perhaps this fiberglass will help date the work.

I'm really really glad that I tore out the plaster. There was some mold where the water had been sitting. There was also evidence of some sort of small rodent's nest in the fiberglass.

Slightly crispy looking knob and tube

Another concern I will be addressing is this bit of knob and tube - it seems that the junction overheated a bit, probably due to being covered with fiberglass.

Library ceiling

Further, this joist has a disconcerting crack in it - I'll probably be sistering it up before everything goes back together.

Library ceiling

I'm not going to ask about the various loose pieces of wood here.

Insulation in the library ceiling

Finally, while insulating hot water pipes is important, I'm not sure that notching joists to this extent is the proper course of action in order to accommodate the insulation.

4 comments:

Lotta Dahl said...

wish I had a library! GORSH!

Good luck with the ceiling. Our livingroom ceiling needs to be replaced after the radiator bust upstairs. I'm eaer to see your finished product!

Shane said...

I think the burn mark behind the K&T wiring isn't from it actually getting hot, but from the person who soldered the lines together. With our demolition, I noticed a lot of hot spots like that as well, and they are always at a tape joint, which makes me think it was just the heat source for the solder if it was even used.

HMC said...

yes, it's common to have little "burn" marks from knob and tube wiring from when they soldered it together way back in the day...

Christopher Busta-Peck said...

Thank you for the update regarding the knob and tube. That makes me a bit more comfortable.